Transformers
Power transformers are used to increase voltage levels to enable long-distance electric transmissions without a frequency change. In an electronic system, the term power transformer is used to provide a number of AC supplies of appropriate voltages and values of current from a public electricity supply.
Advantages
- Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Maecenas porttitor congue massa. Fusce posuere, magna sed pulvinar.
- Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Maecenas porttitor congue massa. Fusce posuere, magna sed pulvinar.
- Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Maecenas porttitor congue massa. Fusce posuere, magna sed pulvinar.
- Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Maecenas porttitor congue massa. Fusce posuere, magna sed pulvinar.
Key Features
- Designed for 25 years of trouble-free performance
- Design conforms to IS 2026, BS 171, IEC 76, and other relevant standards
- Low power loss and low noise
- Designed to withstand electrical impulses, thermal, and dynamic stresses
- Optimum utilization of active materials for compactness
- High performance with life extension and loading flexibility
- Modern manufacturing techniques to ensure cost effectiveness and reliability
Specifications
- 3 phase, 50Hz in voltages of 11kV, 22kV, 33kV, 66kV, 110kV, and 132kV
- Off-circuit tap changer to provide ± 5 %, ± 7.5% & +5% to -10% taps in steps of 2.5%
- On-load tap changer to provide standard range of +5% to -15% taps in steps of 1.25%, 1.7%, 10-21 % @@ 1.75%, and can be custom built for any other ranges
- OLTC can be internally/externally mounted as per requirement
- Class A, uniform/non-uniform insulated
- Vector group Dyn 11, YNd 11, YNyn 0
- Continuous duty, double copper wound
- Painting as per IS/IEC standards
- Both HV and LV side outdoor bushings or cable boxes
- Cooling radiators/fans
- Standard fittings as per IS/IEC standards
- Buchholz relay with alarm and trip contact with shut off valves
- Oil temperature indicator with alarm and trip contact
- Winding temperature indicator with alarm and trip contact
- Magnetic oil level gauge with alarm contact
- Marshaling box to house oil temperature indicator and winding temperature indicator
- Cooler control unit
- Neutral current transformer
Manufacturing Process
- Winding
- All windings are made by experienced and qualified winders with at least 2 years of experience.
- Dry type windings are made on fiber glass mandrels to ensure that there is no inadvertent tearing of the insulations.
- All windings are designed to withstand short circuits and minimize copper usage.
- Windings are made using either copper or aluminum, and can be offered for oil-filled transformers, VPI dry type transformers or cast resin transformers.
- Core Assembly
- Core used is grain oriented steel, manufactured and designed considering the Step Lap method, including mitred joints.
- Using optimal design and manufacturing processes, air gaps are reduced between yokes and legs, reducing noise and losses.
- Core is bound and costed with a special resin which further reduces noise and losses.
- Core is sourced from quality vendors and processed on automated machines to ensure proper 45 degree edging.
- Each core is inspected and losses are measured prior to the next process.
- Core Coil Assembly
- Windings are taken after consolidation and placed on individual limbs of cores.
- Proper insulation scheme, spacers, and routing of cables is ensured.
- Reblading, brazing of busbars and final fittings are completed.
- Core coil assembly is dried for over 12 hours at up to 105 degrees, until completely dry.
- 33 kV and above are processed under vacuum.
- Final Assembly
- Fully dried and consolidated core coils are taken and inserted into tanks.
- After tightening, fixing and cover closure, fittings and accessories are mounted.
- Tanks are pressure tested for 4 hours in "Hot Oil Condition”.
- Transformers are painted and paint thickness is checked and maintained.
- Custom painting systems according to customer's requirements are offered in Epoxy, Hot Zinc Spray, Powder Coating and Polyurethane.
- Testing & Inspection
- All transformers are tested in our Lab according to National and International Standards (IS:2026, IEC 76, etc.)
- Voltage ratio
- Winding resistance
- Impedance voltage
- No load and load losses
- No load current
- Dielectric tests
- Noise level measurement
- DGA - Dissolved Gas Analysis for testing oil
- Harmonic measurement and analysis
- Temperature rise test plant
- Vacuum and pressure test plant
- Oil test facilities
- Specific type tests at approved laboratories can be offered such as:
- Measurement of zero sequence impedance
- Lightning impulse test
- Dynamic short circuit test